Supplier & distributor of wide range of compensator, APFC panels, harmonic block filters, modular capacitor, activcomp, and energy management system, from Chennai - India

Indo Swiss Electricals & Enterprises

Inquiry Basket (0)  

PF Compensator


Click here for an enlarged view
PF Compensator
Safe and reliable PF Compensator of high performance catering to suit the demands and requirements of the clients and the industry. The main features of the PF Compensator are:-

  • Compact wall mounting series for small to medium industries

  • Available upto 100 KVAR rating

  • Suitable for both balanced and unbalanced load

  • Advanced 3-phase controller with inbuilt load analyzer

  • Axial flow fan controlled through thermostat

  • Upto 3 year warranty with long life LL-10 capacitors


It is very important to ensure that electricity is correctly used. Every piece of equipment must be designed to ensure maximum global efficiency in transforming the source of energy into work. Among the measures that enable electricity use to be optimized, improving the power factor of electrical systems is the most important. Utility companies offer incentive to consumers in form of discount on KWH charges or less unit rates if billing is done in KVAH instead of KWH.

It is a known fact the electricity users relying on alternating current – with the exception of heating elements – absorb from the network not only the active energy they convert into mechanical work, light, heat, etc, but also an inductive reactive energy whose main function is to activate the magnetic fields necessary for the functioning of electric machines.

The power factor is thus the ratio between active power and apparent power (vectorial sum of active and reactive power), an indicator of the quality of facility’s electric system since the lower the power factor is, the higher the inductive reactive component will be in relation to the active component.

It is possible to produce reactive energy, where necessary, by installing power capacitors or automatic power factor correction systems. Capacitors absorb a current that is 180º out of phase with the inductive reactive current; the two currents are algebraically summed together so that circulating upstream from the point of installation of the capacitor is a reactive current that is equal to the difference between the inductive and capacitive currents. The exchange occurs between the capacitor and user; this is why we say that they capacitor supplies reactive energy to the user. These come equipped with following outstanding features
  • Incomer TP MCCB35KA

  • Micro processor based Neptune Phasetrac range of 3 phase P.F. controller

  • Inbuilt 3 phase Analyzer

  • Compact wall mounting series with zinc passivated side clamps

  • Front louvers with Axial Flow Fan and Thermostat

  • Heavy Duty specially designed Neptune Capacitor Duty Contactors with high thermal current withstand capacity.

  • MCBs for control circuit protection

  • HRC Fuse or MCB (Series –D) for backup protection of capacitor banks.

  • High electrolytic grade Aluminium Busbar installed on SMC TP supports

  • Discharge resistors (MOR)

  • Standard 1 year warranty with NSL-10 Capacitor or 3 year warranty with long life LL-10 Mono 16 Capacitors.

  • Powder Coated –RAL 7035, Structure Finish.



General Characteristics

Control Module with Data Logger
  • Measurement of A, V, PF, Cosø,W, VAR, VA, ?W, ?VA, ?Var etc.)

  • Sense 1% of load current.

  • Auto manual mode selection with indicator light.

  • Automatic calculation of C/k value.

  • Program entry for targeted Cosø value.

  • Number of capacitor steps are user definable

  • The consequent switching time between capacitor steps is adjustable from 2 to 50 seconds.

  • C+ NORMAL/C-condition lights indicate actual system state.

  • Over voltage, insufficient compensation, over compensation state, alarm indicator lights with output contact.

  • Adjustable programmable over voltage protection for capacitor banks.

  • Micro controller based digital design complying with international standards.

  • Flush mounting with rear panel connectors.

  • Designed to use with current Transformer (…/5A).



Electrical and General Characteristics
  • Power range:12.5 –100 KVAR (440V)

  • Mains voltage (working voltage): standard 440V (other voltage on request)

  • Rated frequency: 50 HZ

  • Altitude: =2000 m a.s.I3

  • Relative humidity: 90% max.at 35ºC

  • Duty: continuous

  • Temperature class: 25 + 55ºC

  • Power supply line: Three – phase + ground + neutral (for440V mains version only)

  • Relay current input signal: from CT on line../5A

  • Relay voltage input signal: picked up internally.



Installation
  • Indoors, wall-mounted, in ventilated, non-dusty environment, away from direct sunlight.

  • Cable inlet from top



Disconnecting Switch
  • TP MCCB – 35 KA breaking capacity.



Mechanical Structure
  • The basic structure is made of white CRCA steel sheet with mounting plate zinc galvanized.

  • The outer steel structural work is painted with cleaning treatment, degreasing, phosphating 70mm thickness, paint with epoxy powder colour RAL7035.

  • Louvers on front door with Axial Flow Fan.

  • Capacitor mounted on side openable section from outside – offering easy replacement.



Wiring and Busbar
  • HR Copper wires are used for all the wiring connecting to electrolytic grade Cu./AI. Busbar section.



Fuses / MCBs for Backup protection
  • HRC Fuse link with base

  • The fuses are of 80KA breaking capacity

  • Series–D TP MCBs for backup protection (optional)



Conductors
  • Equipped with heavy-duty capacitor duty contractor with early make contacts.

  • Coil voltage 230V, 50Hz.



Capacitors
  • Series NSL-10 floppy cap single–ph. elements wired in a delta connection rated 450V.

  • Optionally long life LL-10 mono16 series capacitors, rated 450V.



Protection Devices
  • Each capacitor bank is equipped with discharge devices capable of reducing the residual voltage to below 10% of the rated capacitor voltage in about 30 seconds.



Screening Inspection 100%

Each automatic system manufactured undergoes the following tests and inspections:
  • Visual and dimensional inspection

  • Check on mechanical efficiency

  • Insulation test, 2.5 Kv for 1 min.between phases and ground.

  • Check on electrical efficiency at 440V, with verification of the total capacitance of the capacitors installed in the system.






Content Copyright © Indo Swiss Electricals & Enterprises 2008, All Rights Reserved