| Supplier and distributor of wide range of compensator, APFC panels, harmonic block filters, modular capacitor, activcomp, and energy management system, from Chennai. |
|
|
Automatic power factor correction system
We manufacture automatic power factor correction system of accurateness and high precision. - Compact floor mounting modular series for medium to large industries
- Available upto 1000 KVAR rating
- Suitable for both balanced and unbalanced load
- Advanced 3 phase controller with inbuilt Load Analyzer
- 3 Phase – Energy Analyzer with Data Logger
- Auto Manual selection through Selector Switch
- Axial Flow/Centrifugal Fan controlled through thermostat
- Upto 3 years Warranty with Long Life LL-10 Capacitors.
Life Line Series Automatic Power Factor Correction SystemIn Life Line Series P.F. Compensation System the power range goes from 50 KVAR to 1000 KVAR. These are designed for medium to large load networks. These are highly reliable, cost effective for maintaining high network power factor. These are ultimate solution for compensation of unbalanced loads. The compensation is released by measuring the reactive power of the system, through 3 CTs from all 3 phases. This makes it best suited even for most unbalanced loads apart from balanced loads. They come equipped with following outstanding features: - Incomer TP MCCB / ACB as per rating.
- Micro processor based Neptune Phasetrac range of 3 phase P.F. Controller with inbuilt Load Analyzer
- Inbuilt 3 phase Energy Analyzer with Data Logger
- Modular floor mounting system
- Side / front louvers with Axial Flow / Centrifugal Fan and Thermostat.
- Heavy Duty specially designed Neptune Capacitor Duty Contractors with high thermal current withstand capacity
- MCBs for control protection
- Auto/Manual selection through Sel. Switch
- HRC Fuses/MCCB-35 KA (optional) for backup protection of capacitor banks.
- High electrolytic grade Aluminium Busbar installed on TP supports
- Discharge resistors (MOR)
- Standard One year warranty with NSL-10 capacitor or three year warranty with long Life LL-10 Mono 16 Capacitors.
- Powder Coated-RAL 7035/Neptune Blue, Structure finish.
- Bottom entry system available with option of front glass.
> General Characteristics Control Module with Data Logger - Measurement of A, V, PF, Cosø,W, VAR, VA, ?W, ?VA, ?Var etc.)
- Sense 1% of load current.
- Auto Manual mode selection with indicator light.
- Automatic calculation of C/k value.
- Program entry for targeted Cosø value.
- Number of capacitor steps are user definable
- The consequent switching time between capacitor steps is adjustable from 2 to 50 seconds.
- C+ NORMAL/C-condition lights indicate actual system state.
- Over voltage, insufficient compensation, over compensation state, alarm indicator lights with output contact.
- Adjustable programmable over voltage protection for capacitor banks.
- Micro controller based digital design complying with international standards.
- Flush mounting with rear panel connectors.
- Designed to use with current Transformer (…/5A).
Data Logger Module with Energy AnalyzerEnergy analyzer with data logger is having facility to record and display all the 3 phase parameters of mains where PFC system is connected. The recording is carried out in inbuilt data logger. Lit is possible to log the data with adjustable time difference of 1 mint to 24 hours. Just the same manner it is possible to display (optional) all the electric parameters pertaining to PFC system in control module. The parameters for PFC panel can also be logged in same way. The energy analyzer is having real time clock and date. The 3 phase 32 parameters for mains and PFC systems are available with logging facility to know working efficiency of complete system. Electrical and General Characteristics - Power range: 50-1000 KVAR (440V)
- Mains voltage (working voltage): standard 440V (other voltage on request)
- Rated frequency:50 HZ
- Altitude:- 2000 m a.s.I.
- Relative humidity: 70% max. at 20ºC
- Duty: continuous
- Temperature class: 25 + 55ºC
- Power supply line: Three – phase + ground + neutral (for440V mains version only)
- Relay current input signal: from CT on line…/5A
- Relay voltage input signal: picked up internally.
Installation - Indoors, wall-mounted, in ventilated, non-dusty environment, away from direct sunlight.
- Cable inlet from top or bottom.
Capacitors - Series NSL-10 Floppy Cap single–ph. elements wired in a delta connection rated 450V.
- Optionally Long Life LL-10 Mono16 Series Capacitors, rated 450V.
Protection Devices - Each capacitor bank is equipped with discharge devices capable of reducing the residual voltage to below 10% of the rated capacitor voltage in about 30 seconds.
Screening Inspection 100%Each automatic system manufactured undergoes the following tests and inspections: - Visual and dimensional inspection
- Check on mechanical efficiency
- Insulation test, 2.5 Kv for 1 min., between phases and ground.
- Check on electrical efficiency at 440V, with verification of the total capacitance of the capacitors installed in the system.
|
|