Supplier and distributor of wide range of compensator, APFC panels, harmonic block filters, modular capacitor, activcomp, and energy management system, from Chennai.

Indo Swiss Electricals and Enterprises

Inquiry Basket (0)  

PFC System with Harmonic Block Filters


Click here for an enlarged view
PFC System with Harmonic Block Filters
We, at Indo Swiss Electricals, are engaged in dealing and supplying PFC systems with harmonic block filters.

  • Floor mounting series for medium to large industries

  • Available from 125 to 1000 KVAR rating

  • Advanced 3 phase controller with inbuilt Load Analyzer

  • 3 phase Energy Analyzer with Data Logger (Optional)

  • 3 CT or Single CT input for controller

  • Auto Manual selection through Selector Switch

  • Axial Flow/Centrifugal Fan controlled through thermostat

  • Upto 3 years Warranty with Long Life LL-10 Capacitors

What Do P.F. Correction Capacitors Have To Do With Harmonics?

In an industrial plant containing power factor correction capacitors, harmonics distortions can be magnified due to the interaction between the capacitors and the service transformer. This is referred to as harmonic resonance or parallel resonance. Often, harmonic-related problems do not show up until capacitors are applied for power factor correction.

Components of Detuned Systems
Controller–Single Phase or 3 Phase
  • Measurement of A, V, PF, Cosø,W, VAR, VA, ?W, ?VA, ?Var etc.)

  • Sense 1% of load current.

  • Auto Manual mode selection with indicator light.

  • Automatic calculation of C/k value.

  • Program entry for targeted Cosø value.

  • Number of capacitor steps are user definable

  • The consequent switching time between capacitor steps is adjustable from 2 to 50 seconds.

  • C+ NORMAL/C-condition lights indicate actual system state.

  • Over voltage, insufficient compensation, over compensation state, alarm indicator lights with output contact.

  • Adjustable programmable over voltage protection for capacitor banks.

  • Micro controller based digital design complying with international standards.

  • Flush mounting with rear panel connectors.

  • Designed to use with current T/F (…/5A).


Data Logger Module with Energy Analyzer (Optional)
Energy analyzer with data logger is having facility to record and display all the 3 phase parameters of mains where P.F.C. systems in connected

Capacitors Banks
We deal in the Neptune–Ducati company’s range of capacitor banks, which use capacitor modules from M/s Ducati energia s.p.a, Italy. Due to the technological innovation of self–heating metallized polypropylene, the rated power of 50 KVAR is achieved in just one 3 phase element with very compact dimensions and a much higher life expectancy in comparison with other models. These new long-life capacitors Mono16 and Modulo50 reach an expected life of more than 160,000 hours and a size reduction upto 40% against the technologies so far applied with low loss of 0.2W/KVAR, with 4 in capabilities and oil impregnation, the performance of these capacitors are much better in comparison to other technologies available in market like gas filled and dry type.

Harmonic Reactors
Neptune Filter Circuits are designed as three-phase reactors with an iron core and air gap. Harmonic Filter Reactors are made out of high quality material and very stringent quality control. It has properties like low temperature rise and lower flux density so that it can operate in worst conditions of ambient and harmonic overloads. These offer very good degree of linearity and low losses. Cheaper and non-linear reactors may trigger undesirable chain phenomena during period of operation with high harmonic values, such as reduction in the inductance with consequent increase in the resonance frequency of the LC group, which would drain off more harmonic current, further reducing its inductance and overload the reactor more and more. Reactors are available with filtering factor of 5.6%, 7% and 14% as per standard ratings. Any other filtering factor and rating can be developed on request.

Other parts of Detuned systems
  • Heavy Duty TP contactors for switching

  • HRC fuses

  • ACB or MCCB as incomer


Activcomp
Neptune can also offer fast Thyristor switched transient free system for power factor correction and harmonic filtration.

Electrical and General Characteristics
  • Power range:125 – 1000 KVAR (440V)

  • Mains working voltage 415-440V (other voltages on request)

  • Rated frequency: 50 Hz

  • Altitude: =2000 m a.s.I

  • Relative humidity:70% max.at20ºC

  • Duty: continuous

  • Ambient temperature class:- 5+45ºC

  • Power supply line: Three phase + ground + neutral (for control only) in 3 phase controller

  • 3 phase + ground in single phase controller

  • Relay current input signal: from 3 no’s or I no.CT on line…/5A as per controller type.

  • Relay voltage input signal: picked up internally.






Content Copyright © Indo Swiss Electricals and Enterprises 2008, All Rights Reserved